- Full Power at Wide Output Current Range (Constant Power)
- Adjustable Output Current (AOC) with Programmability
- Isolated 0-10V/PWM/Resistor Dimmable / 3-Timer-Modes Dimmable
- Adjustable Dimming Curve
- INV Digital Dimming, UART-Based Communication Protocol
- Dim-to-Off with Standby Power ≤ 0.5 W
- Minimum Dimming Level with 5% or 10% Selectable
- Hold Time Adjustable
- Fade Time Adjustable
- Always-on Auxiliary Power: 12Vdc, 250mA, 3W (Transient Peak Power up to 10W)
- Low Inrush Current
- Output Lumen Compensation
- End-of-Life Indicator
- Input Surge Protection: DM 6kV, CM 10kV
- All-Around Protection: IUVP, IOVP, OVP, SCP, OTP
- IP66/IP67 and UL Dry/Damp/Wet Location
- TYPE HL, for Use in a Class I, Division 2 Hazardous (Classified) Location
- 5 Years Warranty
Life Time
113,000 Hours @230Vac input, 80% Load and 70°C case temperature.
Dimensions
Inches (L x W x H)
9.57 × 3.54 × 1.71
Millimeters (L x W x H)
243 × 90 × 43.5
Certifications
Adjustable Output Current Range(mA) | Full-Power Current Range(mA) | Default Output Current(mA) | Output Voltage Range(Vdc) | Max. Output Power(W) | Typical Efficiency | Typical
Power Factor |
Model Number | |
120Vac | 230Vac | |||||||
105-1500 | 1050-1500 | 1400 | 133-381 | 400 | 94.5% | 0.99 | 0.96 | EUM-400S150MT |
715-9100 | 7150-9100 | 8350 | 24-56 | 400 | 94.0% | 0.99 | 0.96 | EUM-400S910MT |