- DALI-2 D4i Certified
- Offers Intra-Luminaire Solutions and Health Monitoring
- Integrated 16Vdc Bus Power Supply based on DALI-2
- Wireless Programming via Near Field Communication (NFC)
- Compatible with Zhaga Book 24 Programmers
- Integrated AC Power Monitoring with High Accuracy up to ±1%
- Controls-Ready
- Always-On Auxiliary Power: 24Vdc, 125mA, 3W (Transient Peak Power up to 10W)
- Dim-to-Off
- Isolated Dimming Controls:
- Multiple Timers
- Optimized, More Compact Form Factor
- High Level of Built-in Surge Protection:
- 6kV DM, 10kV CM
- End-of-Life Indicator
- Thermal Sensing and Protection for LED Module
- Simplified Design for Easier Hi-Pot Testing
- Output Lumen Compensation
- SELV Output Models Available
- Input Under Voltage (IUV) and Input Over Voltage IIOV) Protection
- IP66 and IP67 and UL Dry, Damp, Wet Location
- UL Class P
- TYPE HL, for use in a Class I, Division 2 Hazardous
- 7 Year Warranty
Life Time
112,000 hours @ Case Temperature 70°C
Dimensions
Inches (L x W x H)
8.82 x 3.15 x 1.75
Millimeters (L x W x H)
224 x 80 x 44.5
Certifications
Full-Power Current Range | Default Output Current | Input Voltage Range | Output Voltage Range | Max. Output Power | Model Number |
---|---|---|---|---|---|
700 – 1050 mA | 700 mA | 90 ~ 305 Vac 127 – 300 Vdc |
153 – 457 Vdc | 320 W | EUM-320S105BT |
1050 – 1500 mA | 1400 mA | 107 – 305 Vdc | EUM-320S150BT | ||
1750 – 2500 mA | 2100 mA | 64 – 183 Vdc | EUM-320S250BT | ||
2850 – 5000 mA | 4900 mA | 32 – 112 Vdc | EUM-320S500BT | ||
5350 – 7600 mA | 6700 mA | 21 – 60 Vdc | EUM-320S760BT |
File Name
|
---|
LED Driver Installation Guideline (Updated September 2018)
|
Programming Interface Device Driver Install First (Updated March 2015)
|
Design-in Guide for Programming Drivers (Updated September 2018)
|
Inventronics Constant Power Programmer Manual Instruction (Updated December 2020)
|